Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19OT00582

Parcel: 10509547A


Addresses:

65 W RIVER RD


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T19OT00582

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2019 SIGN SITE REVIEW Approved Revised engineering approved for use of spread footers with drive thru signs, by Randy McCoy.
08/13/2019 SIGN SITE REVIEW Approved Engineered drive through canopy approved by structural.
08/07/2019 SIGN SITE REVIEW Continued Received revised sheet for smaller signs and engineering for drive thru canopy w/ order sign.
07/31/2019 SIGN SITE REVIEW Partial Approval RE: sign permit review
For: new Starbucks - building and detached signs
AT: 65 W River Road
Permit: T19OT00582
Reviewer: H. Thrall
Date: 7/31/2019 (2nd review)
Status: PARTIAL APPROVAL

1) Understood the smaller wall signs indicating drive thru location are interior site signs, as are the traffic directional signs. As the application indicates these wall signs are illuminated, provide a separate sheet for that sign that can be added to the overall package - showing:
A) 4400K max color temperature for internally illuminated signage
B) Shut off switch location
C) Volts, amps, circuits
D) Breaker panel location for inspections
E) Mounting notation - size / type / number of bolts/screws typ.
F) Timer

2) Provide engineering for drive thru canopy structure, as the review of the structure takes place during sign review rather than building plan review.

Information may be sent to Heather.Thrall@tucsonaz.gov
07/25/2019 SIGN SITE REVIEW Continued Proposal resubmitted 7/25/19.
06/24/2019 SIGN SITE REVIEW Continued RE: sign permit review
For: new Starbucks - building and detached signs
AT: 65 W River Road
Permit: T19OT00582
Reviewer: H. Thrall
Date: 6/24/2019

1) Provide building frontages on copy of approved development or building plan (contractor emailed with this data 6/24/19) for verification.

2) Attached sign area is 1.25 x each building elevation with a secondary cap of 250 square feet per tenant. Sign area proposed on renderings will be within the sign area allowance.
A) clarify size of the small "drive-thru" signs on each building elevation so as to be noted as interior site signs due to size. May require electrical permit.

3) Detached signage is all interior site signage and will be reviewed for electrical and structural only, as needed. No freestanding monument signage is included with this application.

4) NEC. 600 -
A) specify total number of dedicated circuits on drawings for all signs
B) specify location of power panel & dedicated circuits for inspections for mounted signs
C) specify location of power panel & dedicated circuits for detached signs for inspections

5) Outdoor Lighting Code Ch 4 & 5
A) specify that ALL internally illuminated signs shall not exceed 4400k color temperature per 501.3

6) All drive -thru menu boards - specify if digital displays.
A) If digital displays, specify shall dim to 200 NITS of light brightness from sunset to sunrise and note method of dimming (i.e. light sensor laster, photocell, etc.)

6) Structural - IBC 2018
A) specify if weld notes for menu boards refers to shop welds. Note that field welds require engineered plans and special inspections.

Remainder of engineering will be reviewed upon response to above.

Send revisions to Heather.Thrall@tucsonaz.gov