Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T19OT00253
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2019 | SIGN SITE REVIEW | Approved | Received TDOT as built diagram for Stone side of development. Distance from curb to property line off Stone is just over 15'. Monument sign setback of 30' off Stone side is sufficient and relegates sign to Grant frontage. Grant setback of 20' maintains sign on site (curb to property line is 20'). Watch the setback right at lot line at Grant Road - 20' is at property line. |
|
04/12/2019 | SIGN SITE REVIEW | Continued | Received TDOT data for Grant Road widening as built plans. It is 20' from F.O. Curb to PL. Monument Sign is shown on site on plans for Grant Road side and out of SVT, meeting 20' setback. Just received Stone Avenue side data for that intersection and will examine for setback on 4/15. Emailed contractor courtesy update. |
|
04/09/2019 | SIGN SITE REVIEW | Continued | Revised plan set and engineering received on 4/9/19. | |
04/03/2019 | SIGN SITE REVIEW | Partial Approval | RE: wall and monument sign review For: Star Glass / 1 E Grant Reviewers: H.Thrall / R. McCoy Date: 4/4/19 Permit: T19OT00253 1) Acknowledged recent roadway widening done to site changes configuration for Grant/Stone property line boundaries. No Dev. Plan filed for recent site alterations. Ok to use aerial photo for site plan data. Staff assisting with ROW plans for SVTs and lot line lengths to assist contractor. Acknowledged sign area proposed within allowances with data as presented, as full premise shown on presented aerial plan. Acknowledged freestanding sign permitted. 2) Bisect corner to show which street frontage freestanding sign is to count toward or if it will be an "intersection corner sign".(Take curb lines straight out to meet, cut in half with dashed line to create bisection.) 3) Outdoor Lighting Code both signs: add 4400K maximum internal temperature notation. 3) Label pole cover. 4) Structural (IBC 2018: 102.4.2, 1600 / Appendix H 105.3): Randy McCoy monument sign: A) dimension all compoments and outermost extents of cover B) revise footer to 30" width, per engineering for structural surface over within 75 sq.ft. range, using furthest extents of sign. C) note shop welds, or if site welds -address via engineered plans with special inspection required. D) footer inspection required |