Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T19OT00084
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2019 | SIGN SITE REVIEW | Approved | Revised engineering approved. | |
| 04/16/2019 | SIGN SITE REVIEW | Continued | Engineering received for review of Craycroft monument sign -approved via SSDO process (T19SA00105). | |
| 04/01/2019 | SIGN SITE REVIEW | Continued | Director's Notice of Decision issued with approval (no conditions). Allow: 1) install a 2nd freestanding (monument) sign on Craycroft frontage for overall premise with less than 850' of street frontage & 2) for that sign to serve an apartment complex at a sign area increase from 20 to 32 square feet, as shown on submitted plans. Appeal period ends 4/15/19. All documents in T19SA00105 as of 4/1/2019. Updated file for permit review. |
|
| 03/31/2019 | SIGN SITE REVIEW | Continued | DP sent in review of the SSDO request on 3/31/19 | |
| 03/15/2019 | SIGN SITE REVIEW | Continued | 3/15/19 Singular Sign Design Option request submitted to Design Professional in lieu of SDRC quorum. Case T19SA00105 | |
| 03/01/2019 | SIGN SITE REVIEW | Continued | Contractor submitted additional documents for review - 2nd sign for site - off driveway interior to overall subdivision. Review continues for MSP referral. Appears now SSDO - singular sign design option - submittal, focus is on varying one sign for scenic road frontage of overall premise and also for sign area for apartment region of premise: SDRC Review: The Singular Sign Design Option (SSDO) request is to vary: 1) Primary Monument Sign - request to exceed 20 square feet maximum sign area of a freestanding sign (for approximately 32 square feet) for an multi-family residential development premise in the Scenic Corridor Zone District. 7A.11.E.3.b 2) Primary Monument Sign - along Craycroft Road, request to exceed the number of allowed freestanding signs along a scenic corridor with less than 850' of street frontage for the overall PAD-22 premise. (UDC 7A.11.E.3.a.) The Craycroft frontage of the Rio Verde Village PAD is approximately 640' feet, which allows for the one (1) existing monument sign. The proposed monument sign would be the 2nd freestanding sign within this described frontage. (For reference, see prior sign permit for monument serving commercial region of premise.) |
|
| 02/25/2019 | SIGN SITE REVIEW | Continued | RE: revised plans submitted For: The Place at Riverwalk AT: 3510 N Craycroft Sign District: Scenic Corridor Zone / PAD-22 Date: 2/25/2019 Reviewer: H. Thrall Revised plans submitted, requires a master sign program: A) to exceed number of signs along scenic corridor (Craycroft) B) to exceed sign area of detached sign for multi-family use in scenic district C) Master sign program applications sent to contractor to begin process. D) Public utility easement either requires written permission from utilities for sign placement or abandonment and re-dedication of easement area adjacent to subject property to sign location. Further discussion forthcoming. |
|
| 01/28/2019 | SIGN SITE REVIEW | Continued | RE: Monument Sign review FOR: The Place at Riverwalk (Apts) AT: 3510 N Craycroft Rd. Sign Permit: T19OT00084 Reviewer: H. Thrall Date: 1/28/19 1) Acknowledged easement recordation on block 8 at driveway entry to overall development for purposes of sign display dedicated for block 9 (apts). A) To accomplish an on-site sign for the apartments parcel of block 9, provide updated sign easement that shows continuation from current easement outline to property line of block 9 (apts), running along driveway. Continuation to be a minimum of 1' wide - ok for access across. Sign easement should have maintenance agreement, "allowing block 9 owner and representative to access/install/maintain freestanding sign for use of block 9, on block 8, via easement and to utlilize block 8 for such purposes (i.e. I'm referring to allowing parking construction trucks, auger and cement pour use...etc.) Legal description needed for full sign easement. Written property owner consent of block 8 needed for agreement to allow easement on block 8 for use of block 9 signage. 2) The location is along two scenic corridors, per City of Tucson Major Streets and Routes map: River Road and Craycroft Blvd. As such, the Scenic Corridor District of the Sign Standards is the applicable sign district, Unified Development Code (UDC) Article 7A.11.3.E.3.b limits the sign area for a freestanding sign for a multi-family residential use to 20 square feet. The sign cabinet exceeds that and will be referred to the Master Sign Program process. 3) Per 7A.11.3. Scenic Corridor Zone - provide night view drawing to ensure light is emitted only through copy/logos and opaque background provided otherwise. 4) The total number of allowed freestanding signs along Craycroft, excluding the QuikTrip property developed in the county, is 1 sign. This sign will be referred to the Master Sign Program for an additional sign along the Craycroft frontage of the overall development. 5) Grade check underway for height and setback proximities. Acknowledged shown 8' from property line/start of scenic buffer along Craycroft and meets 20' minimum on diagram for setbacks from street curbs. 6) Provide engineering calculations/diagrams for adequate footers for structure with surface area over 60 square feet, per IBC. Further review comments may be forthcoming, depending upon responses and inspection findings. |