Case: T19DV07166

Parcel: 14020009E


Addresses:

5080 S PARK AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
09/11/2019 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TPD: CAUSE OF DAMAGE: VEHICLE INTO DWELLING

LOCATION OF DAMAGE: FRONT BEDROOM

BUILDING: VEHICLE IMPACT CAUSE DAMAGE TO AN EXTERIOR BEARING CMU WALL. THE DAMAGED OPENING SIZE IS ESTIMATED AT 8 X 12 FEET, THE ENTIRE WALL DAMAGED AREA WAS PUSH INSIDE THE BEDROOM. THE INTERIOR WALL DAMAGE IS ESTIMATED AT 8 X 10 FEET, STUDS AN DRYWALL DAMAGE. 5 ROOF TRUSSES ARE UNSUPPORTED AT THIS TIME.



ELECTRICAL: THERE ARE NM CABLES PULLED AND DAMAGED IN THE IMPACT AREA. THE POWER WAS DISCONNECTED BY TEP.




PLUMBING: NA




MECHANICAL: NA



REMARKS: THIS HOME WAS CONDEMNED AND A PERMIT IS REQUIRED FOR REPAIRS. CITY CONTRACTOR WILL SECURE THE DAMAGED OPENING.