Case: T19DV06378

Parcel: 107141740

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/05/2019 INSP - INITIAL CODE ENFORCMENT Approved PARCEL: 107-14-1750 & 107-14-1740
ADDRESS: 2525 N. CASTRO AVE
UNIT NUMBERS AFFECTED: 20-1, 20-2, 19, 19-1, 19-2, 14, 13, 12, 11, 9, AND 1
MULTIPLE ELECTRICAL HAZARDS WERE IDENTIFIED ON 8/6/2019, ENERGIZED OVER HEAD FEEDERS ARE UNSTABLE AND DILAPIDATED. POWER WAS TERMINATED BY THE OWNER'S ELECTRICAL CONTRACTOR AND SECURED A DAMAGED POST WITH A TEMPORARY, ON SITE REPAIR. ENGINEERING AND PERMITS WILL BE REQUIRED TO WORK ON THE PARK'S INFRASTRUCTURE TO THE R-3 ZONED PROPERTY.
VACANT SPACES ARE AS FOLLOWED: 15, 16, 17, 18, 21, 22, 35, and 36 (BASED ON MY BEST JUDGMENT MOBILE UNITS DO NOT COINCIDE WITH MARK UNITS) THERE ARE OTHER VACANT SPACES WITHOUT ANY TYPE OF INDICATION, WILL PROVIDE AERIAL WITH MARKED VACANT SPACES)
RV'S ARE NOT AN APPROVED USE IN AN R3 ZONE, PROPERTY MUST HAVE A ZONING SITE PLAN APPROVED FOR THE MIX USE OF R.V.S, MOBILE HOMES AND THE DUPLEXES ON THE PROPERTY.
MULTIPLE OVERHEAD FEEDER'S POST AND PEDESTALS ARE EITHER UNSTABLE, DILAPIDATED OR HAVE COLLAPSED THEY ARE IN NEED OF REPAIR OR REPLACEMENT. OVER HEAD FEEDERS ARE TANGLED, NOT PROPERLY ANCHORED THE ABUTTING POST. FEEDERS ARE WITHIN 8 FEET OF THE DWELLING ROOF TOPS. NON PERMITTED OUTDOOR LIGHTING ARE DIRECTLY CONNECTED TO THE OVERHEAD FEEDERS WITHOUT OVER CURRENT PROTECTION. MAIN SERVICE PANEL, DOWNSTREAM PANELS AND PEDESTALS ARE LACK GROUNDING OR GROUNDING NEEDS TO BE VERIFY IF MODIFICATIONS ARE CODE COMPLIANT AND MEET MANUFACTURES REQUIREMENTS. MAIN DISCONNECT AND DOWNSTREAM PANELS LACK OF PROPER LABELING/DIRECTORY. DOWNSTREAM PANELS AND PEDESTALS HAVE UNUSED OPENINGS, MODIFICATIONS AND OR MISSING DEAD FRONTS. THERE IS UNPROTECTED AND OR DAMAGED CONDUCTORS, CONDUIT THAT ARE EXPOSED TO THE ELEMENTS. THERE ARE MULTIPLE CIRCUIT BREAKERS MIXED WITH NON COMPATIBLE EQUIPMENT AND OR UN-READABLE. THERE ARE MAIN SERVICE EQUIPMENT BEING USED IN A NON CODE COMPLAINT METHOD AGAINST MANUFACTURES LISTING.
UNIT NUMBER 20-1 AND 20-2: WOOD MEMBER FOUNDATION IS DILAPIDATED CURRENTLY BEING SUPPORTED BY CLAY PIPING AND SHOWING SIGNS OF WOOD ROT AND DECAY. THE UNIT'S INTERIOR LACK OF FIRE SAFETY EQUIPMENT. EGRESS HAS BEEN RESTRICTED WITH WINDOW MOUNT AC UNITS OR BOARDING. OCCUPANTS ARE USING ALTERNATIVE POWER VIA BATTERIES AND ABUSING THE USE OF EXTENSION CORDS FOR SUPPLEMENTAL POWER FOR INTERNAL USE. INTERIOR ELECTRICAL HAS BEEN MODIFIED TO A NON CODE COMPLAINT METHODS. THE DWELLINGS LACKS OF AN APPROVED FURNACE OR HEATING APPLIANCE CAUSING THE OCCUPANTS TO USE THE STOVE AS AN ALTERNATIVE.
UNIT NUMBER 19-1 AND 19-2: PLUMBING IS NOT PROPERLY CONNECTED OR IS DAMAGED CAUSING A SEWER LEAK UNDERNEATH THE WOOD FLOOR RAFTERS TO BOTH UNITS. THE UNIT'S INTERIOR LACKS OF FIRE SAFETY EQUIPMENT. EGRESS HAS BEEN RESTRICTED FROM THE MODIFIED FLOOR PLAN, AND UNIT'S APPLIANCES. INTERIOR ELECTRICAL HAS BEEN MODIFIED TO A NON CODE COMPLAINT METHOD. UNSTABLE FLOORING IN THE BATHROOM HAS SIGNS OF DETERIORATION AND SHIFTING. THE NEWLY INSTALLED ELECTRIC WATER HEATER WITH MANUFACTURE LABEL OF 2018 HAS BEEN INSTALLED WITHOUT A PERMIT BLOCKING THE DWELLING'S WINDOW.