Case: T19DV06061

Parcel: 115050690


Addresses:

214 W SAHUARO ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
07/25/2019 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY, SUPERVISOR, UNIT 4 .INSPECTION RESULTS ARE AS FOLLOWS: THE PROPERTY HAS TWO DWELLING BUILDINGS. NO PERMIT PLUS ACTIVE FOR THE FOLLOWING: THE REAR UNIT 4 HAS A 200 AMP SERVICE PANEL WHICH INSTALLED WITHOUT A PERMIT, TEP STATED LOCKING RING IS NOT THERE'S AND LOCKING DEVICE WAS BROKEN, OVERHEAD CONNECTION WAS NOT DONE BY TEP. THIS DISCONNECT HAS WITH WIRING DATED 2013, THIS DISCONNECT IS THE SERVICE FOR 5 UNITS WITH THE ADDRESS AT 203 W SAHUARO. THIS MAIN DISCONNECT HAS MULTIPLE CODE VIOLATIONS UNAPPROVED WIRING METHODS, NEW BRANCH CIRCUIT FOR A ROOF MOUNTED MINI SPLIT AC UNIT. NON COMPATIBLE BREAKER. THE DWELLING HAS UNPROTECTED ELECTRICAL EQUIPMENT. THE DWELLINGS INTERIOR IS UNSANITARY WITH WATER DAMAGE TO THE INTERIOR, THERE IS PEX PIPING INSTALLED TO THE EXTERIOR OF THE WESTSIDE OF THE DWELLING ALSO A 2018 GAS FIRED WATER HEATER NON CODE COMPLIANT AND THERE IS A NEW GAS FIRED FURNACE INSIDE THE UNIT. ALL WORK WAS DONE WITHOUT PERMITS. THIS UNIT WAS CONDEMNED. UNSAFE TO OCCUPY. LOAD CALCULATIONS REQUIRED FOR THE SERVICE


UNIT 5 HAS NEW PANEL POWERED VIA UNDERGROUND FEEDER, THIS PANEL LOOKS NEWER. NO GROUNDING SYSTEM, MISSING DEAD FRONT. UNAPPROVED WIRING METHODS. NEW BRANCH CIRCUIT FOR THE ROOF TOP MOUNTED AC UNIT. INTERIOR OF THE HOME HAS MULTIPLE JUNCTION BOXES INSTALLED FOR LIGHT AND SWITCH DEVICES, THE INTERIOR EGRESS BLOCKED AT WINDOW IN SLEEPING AREA. REAR ROOM WAS ENCLOSED IS NOW SLEEPING AREA. NEW GAS FIRED WATER HEATER. NEW PEX PIPING INSTALLED. THE FRONT ATTACHED PORCH HAS NEW WOOD FRAMED POSTS AND BEAMS. TAMPERING WITH TEP EQUIPMENT. THE ABOVE WORK WAS DONE WITHOUT PERMITS\..THIS UNIT WAS CONDEMNED, UNFIT TO OCCUPY