| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2020 | PLUMBING - FINAL | Approved | Water heater and gas ok. Clear gas |
|
| 01/13/2020 | PLUMBING - FINAL | Denied | 1- Shall provide an approved water heater listed for Manufactured Mobile Home. 2- Shall provide a sediment trap at the water heater regulator. 3- Shall extend the water heater t & p drain through the floor and terminate it 6 inches above sub grade. 4- Shall extend the water heater flu vent and terminate it 2 feet above the evaporative cooler. Note: A permit shall be obtained for the gas pressure test prior to inspection. |
|
| 12/26/2019 | PLUMBING - FINAL | Not ready for Inspection | not complete |