Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T19CM09413
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2020 | PLUMBING - FINAL | Approved | Water heater and gas ok. Clear gas |
|
01/13/2020 | PLUMBING - FINAL | Denied | 1- Shall provide an approved water heater listed for Manufactured Mobile Home. 2- Shall provide a sediment trap at the water heater regulator. 3- Shall extend the water heater t & p drain through the floor and terminate it 6 inches above sub grade. 4- Shall extend the water heater flu vent and terminate it 2 feet above the evaporative cooler. Note: A permit shall be obtained for the gas pressure test prior to inspection. |
|
12/26/2019 | PLUMBING - FINAL | Not ready for Inspection | not complete |