Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19CM09413

Parcel: 11803298A


Addresses:

1600 S LA CHOLLA BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T19CM09413

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/23/2020 PLUMBING - FINAL Approved Water heater and gas ok.
Clear gas
01/13/2020 PLUMBING - FINAL Denied 1- Shall provide an approved water heater listed for Manufactured Mobile Home.
2- Shall provide a sediment trap at the water heater regulator.
3- Shall extend the water heater t & p drain through the floor and terminate it 6 inches above sub grade.
4- Shall extend the water heater flu vent and terminate it 2 feet above the evaporative cooler.
Note: A permit shall be obtained for the gas pressure test prior to inspection.
12/26/2019 PLUMBING - FINAL Not ready for Inspection not complete