Permit: T19CM09371

Parcel: 138180150


Addresses:

7226 S 6TH AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/13/2020 PLUMBING - INTERMEDIATE Approved
02/11/2020 PLUMBING - INTERMEDIATE Denied 1- Shall provide boca plates for protection of plumbing on top and sole plates and shield plates missing on North bathroom.
2- Shall provide a water test on the DWV system.
3- There are numerous conductors that are not secured within 6 inches of the box.
02/05/2020 PLUMBING - INTERMEDIATE Denied 1- Shall seal all top plate penetrations with fire rated foam or caulk.
2- Shall provide boca plates for protection of plumbing on top and sole plates.
3- Shall repair all vandalized copper water stub outs and have the water distribution energized at time of inspection request.
4- Shall provide a water test on the DWV system.
5- Shall provide (3) sided blocking on all forced air vents.