Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T19CM08795

Parcel: 138140850


Addresses:

418 W CALLE ANTONIA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/19/2020 PLUMBING - FINAL Approved Clear gas meter
12/19/2019 PLUMBING - FINAL Denied 1- The pressure test was below the required 10 psi. Check the system for leaks.
2- Shall provide a carbon monoxide detector and locate it in the hallway to the bedrooms.
12/03/2019 PLUMBING - FINAL Denied 1- Shall provide a air pressure test on the system.
2- Shall install all gas appliances at time of final inspection.
3- Shall provide a carbon monoxide detector and locate it in the hallway to the bedrooms
4- Shall provide a gas bond on the system