Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T19CM07968
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2020 | PLUMBING - ROUGH, SOIL | Approved | ||
03/11/2020 | PLUMBING - ROUGH, SOIL | Denied | 1- Shall install the Grease Waste system as per section 912 IPC 2018. 2- Shall provide the minimum trap arm distance for the Mop Sink. Reference section 909.3 IPC 2018 3- Retest the system |