Permit: T19CM07201

Parcel: 131090500


Addresses:

1409 S VAN BUREN AV

Inspection Status: Approved

Inspection History: RESIDENTIAL INTERMEDIATE

Date Description Inspector Results Comments
02/27/2020 RESIDENTIAL INTERMEDIATE Approved
01/22/2020 RESIDENTIAL INTERMEDIATE Partial Approval need a complete DWV and washer hammer arresters
01/14/2020 RESIDENTIAL INTERMEDIATE Not ready for Inspection DWV and domestic not on test.
01/07/2020 RESIDENTIAL INTERMEDIATE Denied Loose wire hanging from ceiling in hallway. Rubber fittings not to be used under slab on DWV. Cast-iron DWV not connected were penetrating ceiling. ABS DWV running up hill at laundry. ABS DWV not on test. All penetrations through top plates are to be sealed with fire caulk. Provide fire blocking at furred ceilings. Provide nail plates as needed. This list is not complete inspections stopped at this time.
12/24/2019 RESIDENTIAL INTERMEDIATE Denied no access