Permit: T19CM06692

Parcel: 138111110


Addresses:

325 E HAGEN PL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/20/2019 PLUMBING - GAS PRESSURE TEST Approved Verbal clearance called in at 1:32 pm.
09/18/2019 PLUMBING - GAS PRESSURE TEST Denied 1- Shall provide a carbon monoxide detector and locate it in the hallway to the bedrooms.
2- Shall provide a gas bond on the system.
3- Shall extend and terminate the water heater t & p drain to daylight or provide a water heater drip pan and cap off the drain outlet and extend the t & p drain into the drip pan.
4- Shall position the sediment trap tee in a bullhead position to the water heater gas supply.