Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2019 | ROOF NAILING | Approved | ||
| 11/13/2019 | ROOF NAILING | Not ready for Inspection | Canceled by contractor | |
| 11/08/2019 | ROOF NAILING | Not ready for Inspection | Unable to access for inspection. | |
| 11/07/2019 | ROOF NAILING | Correction Required | Corrections not completed. | |
| 11/07/2019 | ROOF NAILING | Correction Required | 1-Too many nails are overdriven(more than one-eight of an inch; install one properly driven nail between two over driven nails. 2-Block under sheets that have saw kerf. |
|
| 10/24/2019 | ROOF NAILING | Not ready for Inspection | Provide ladder for roof access, truss calx to be on site |