Permit: T19CM06309

Parcel: 13304431A


Addresses:

2121 N EVELYN AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T19CM06309

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/09/2019 ELECTRIC - FINAL Approved Inspected during last visit.
08/30/2019 ELECTRIC - FINAL Correction Required THE NEW SUB PANEL WAS INSTALLED IN CONJUNCTION WITH PERMIT T19BO00078, BUT WAS NOT INCLUDED IN THE SCOPE OF WORK FOR THAT PERMIT. THIS PERMIT WAS ISSUED TO CORRECTLY RECORD THE WORK THAT WAS PERVIOUSLY DONE WITHOUT PERMIT.
08/30/2019 ELECTRIC - FINAL Denied Sub panel installation is ok. There is a 20 amp circuit from the sub panel to feed a timer. From the timer, there is an integral circuit wire feeding a gfi outlet, which tripped when tested, but will not reset. A specification sheet for the timer is needed to determine if it is approved for this wiring schematic. Repair, replace, or eliminate as stated in the timer specs.