Permit: T19CM06267

Parcel: 120073910


Addresses:

413 W COLUMBIA ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS RECONNECT

Date Description Inspector Results Comments
09/12/2019 PLUMBING - GAS RECONNECT Approved Clear gas meter
Verbal clearance called in at 12:00 pm.
09/09/2019 PLUMBING - GAS RECONNECT Denied 1- Shall provide a flu vent for the water heater minimum of 5 feet.
2- Shall provide a gas bond on the system.
3- Shall provide a carbon monoxide detector.
4- Shall secure the gas line drop to the wall for the he dryer.
5- Shall provide 10 psi air test on system.
6- Shall provide a T & P drain for the water heater and terminate it 6 inches above base.