Permit: T19CM06243

Parcel: 14025077A


Addresses:

1230 E ALVORD RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/04/2019 PLUMBING - FINAL Approved
09/26/2019 PLUMBING - FINAL Denied 1- Shall connect the electric conductors to the water heater.
2- Shall provide a T & P drain line and terminate 6 inches above sub grade.
3- Rear hose bib is very loose and requires a vacuum breaker.
4- Shall secure the floppy electric conduit to the water heater.
ANOTHER FAILED INSPECTION WILL RESULT IN A RE-INSPECTION FEE
09/24/2019 PLUMBING - FINAL Denied 1- Shall provide a water hammer arrestor for the dishwasher water supply line.
2- Shall provide water hammer arrestors for the Clothes Washer hot and cold supplies.
09/18/2019 PLUMBING - FINAL Denied 1- Gate locked no access at the time of inspection request.
I could not leave a message when I called 312-4142 because voicemail was not set up.1:27 pm