Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T19CM05544
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2022 | BUILDING PRE-SLAB | Approved | Approved | |
| 12/22/2021 | BUILDING PRE-SLAB | Partial Approval | . Partial. Loading dock apron at East area. Ok to place concrete in progress areas. | |
| 10/14/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #3 at GL: N-U/2-9.5; Level #2.5 at GL: U-X/1-6. Ok to place concrete in progress areas. | |
| 07/28/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Metal deck slab at GL: I-Q/4-12. Ok to place concrete in progress areas. | |
| 07/22/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #2 at GL: 14-24/A.5-Q. Ok to place concrete in progress areas. | |
| 07/12/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #2 at GL 4-14/A-H.5. Ok to place concrete in progress areas | |
| 06/15/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #2; slab at GL: G.5-Q/14-24. Ok to place concrete in progress areas. | |
| 05/14/2021 | BUILDING PRE-SLAB | Partial Approval | Level #2; Section #1 at GL: 5-15/A-H. Ok to place concrete in progress area. | |
| 05/04/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Northeast slab at GL: U/1-3. Termite treated; Ok to place concrete in progress area. | |
| 04/14/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #1 at GL: A-H/13-18. Ok to place concrete in slab area | |
| 04/06/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #1 at GL: G-N/4-10; G-Q/10-15. Ok to place concrete in progress areas. | |
| 03/31/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #1 deck at GL: N-U/2-10. Ok to place concrete in progress areas. | |
| 03/19/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Slab at GL: A-H/12-24; Loading dock at GL: A-H.5/24-25.7. Ok to place concrete in slab areas. | |
| 03/01/2021 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #1 at GL: A-N/15-24. Ok to place concrete in progress areas. | |
| 01/28/2021 | BUILDING PRE-SLAB | Partial Approval | PARTIAL - BASEMENT SLAB AT GL:9.5-17/O-Q. OK TO PLACE CONCRETE IN PROGRESS AREA | |
| 12/16/2020 | BUILDING PRE-SLAB | Partial Approval | Partial. Basement slab at GL: 10-2/M-U. Ok to place concrete in progress areas. | |
| 10/21/2020 | BUILDING PRE-SLAB | Partial Approval | Partial. Level #1 slab at GL: 12/A-G.8. Ok to place concrete in progress areas. | |
| 10/12/2020 | BUILDING PRE-SLAB | Partial Approval | Basement level slab, Nelson Studs tested by special inspector. Ok to place concrete in progress areas. |