Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T19CM05155
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2019 | ELECTRIC - RECONNECT | Approved | OK to clear electric RECN. Service panel was locked up homeowner is telling me TEP locked it up. That’s the only part of the inspection I wasn’t able to complete. | |
| 07/24/2019 | ELECTRIC - RECONNECT | Correction Required | Service panels need 2 Ground Rods, Gas pipe Bonds, and Water pipe Bonds. See licensed electrician for advice. |
|
| 07/22/2019 | ELECTRIC - RECONNECT | Denied | 1. Need smoke detector in each sleeping room and outside of sleeping rooms 2. Need bonding to gas line and water line 3. Need to fill open knockouts on electrical panel with approved covers 4. Need carbon monoxide detector near furnace, or combination co2/smoke detector outside of sleeping rooms |