Permit: T19CM05155

Parcel: 132111860

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T19CM05155

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
07/30/2019 ELECTRIC - RECONNECT Approved OK to clear electric RECN. Service panel was locked up homeowner is telling me TEP locked it up. That’s the only part of the inspection I wasn’t able to complete.
07/24/2019 ELECTRIC - RECONNECT Correction Required Service panels need 2 Ground Rods, Gas pipe Bonds, and Water pipe Bonds.
See licensed electrician for advice.
07/22/2019 ELECTRIC - RECONNECT Denied 1. Need smoke detector in each sleeping room and outside of sleeping rooms
2. Need bonding to gas line and water line
3. Need to fill open knockouts on electrical panel with approved covers
4. Need carbon monoxide detector near furnace, or combination co2/smoke detector outside of sleeping rooms