Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T19CM05139
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2019 | FRAMING | Approved | ||
10/18/2019 | FRAMING | Denied | 1. Need boca fha plates, nailed off, at 1st floor bath abs top plates and at garage rear shearwall abs. 2. Need stud shoes on 1st floor bath abs penetrations. 3. Move duct off furnace flex vent pipe. 4. Need outlet south of patio door, within 6’ of door. 5. Need air balance transfer grill frame above 1st floor bedroom door. 6. Secure toilet flange to floor on 1st floor. |