Permit: T19CM05078

Parcel: 13608032A


Addresses:

2200 S HOUGHTON RD


Inspection Status: Passed

Inspection History: COT - FCON - Fire - Final

Permit Number - T19CM05078

Inspection Description - COT - FCON - Fire - Final

Inspection Status - Passed

Date Description Inspector Results Comments
05/09/2022 COT - FCON - Fire - Final jfordney Approved Entered by JFORDNE1 - OK FOR TCO
05/06/2022 COT - FCON - Fire - Final jfordney Partial Approval Entered by JFORDNE1 - Doors all checked. Keys in knox boxes
05/05/2022 COT - FCON - Fire - Final jfordney Partial Approval Entered by JFORDNE1 - All doors checked. Still need to verify 1738, 1791 a&b, 1040a Make sure L&D doors don't open on pull/smoke
04/27/2022 COT - FCON - Fire - Final jfordney Not ready for Inspection Entered by JFORDNE1 - doors 2nd floor: stair 1 lower left gap 2137 a&b sweeps 2105 center gap 2906, 2246b hardware ALL !ST FLOOR DOORS NEED TO BE CHECKED
04/21/2022 COT - FCON - Fire - Final jfordney Partial Approval Entered by JFORDNE1 - Doors on 2nd floor Need adjustment on closure hardware: ALl ICU SLIDERS 2183, 2137A, 2182, 2025 2102, 2906, East wing north entrance Need smoke seals: 2603, Stair 3 2nd floor, 2211 Need gap adjusted: 2301, 2211, 2252, 2278, 2246, 2274, stair 1 2nd floor, 2272, 2271, 2270, 2269, 2250, 2268, 2246, 2266, 2265, 2244, 2264, 2263, 2262, 2261, TDR 2023, 2026, 2101, 2481, 2442, 2485, 2702a, 2622, 2484, 2603, 2404, 2428, 2486, 2487, 2489, 2441, 2390, 2491, 2492, 2492A, 2434, 2432B, 2406, 2432A, 2134, 2137B, 2137A, 2123, 2133, 2136, 2135, 2132, 2125, 2105 Need fire rating label: 2244, 2245 Lights under EM power: 1791 equipment storage.
04/20/2022 COT - FCON - Fire - Final jfordney Cancelled Entered by JFORDNE1 - per contractor
03/29/2022 COT - FCON - Fire - Final jfordney Partial Approval Entered by JFORDNE1 - Sprinkler system is functioning and alarm is monitoring sprinkler and pump. OK TO OBTAIN TCO FOR EQUIPMENT MOVE IN ONLY
05/19/2021 COT - FCON - Fire - Final JPEELDAVIS Prior to Final Inspectn Entered by JPEELDA1 - Plans approved by MHB 2019. Owner to obtain a State Licensed Facility operatinal permit from TFD Owner to obtain a Flammable & Commubustible liquids permit from TFD Owner to obtain a compressed gas operational permit from TFD A permit shall be obtained from TFD for the fire sprinkler underground A permit shall be obtained from TFD for the fire sprinkler system A permit shall be obtained from TFD for the fire alarm system A permit shall be obtained from TFD for the kitchen fire suppression system