Inspection History Details
Inspection Status: Correction Required
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2019 | ELECTRIC - FINAL | Correction Required | The Grounding Electrode Conductor for 3051 E Proctor Vista has been compromised in the process of Grounding 3049 E Proctor Vista ( these addresses share a weather head and lateral conductors). The water bond for both services has also been installed improperly. Install Code compliant Grounding Electrode Conductor for 3051 E Proctor Vista and a Code Compliant water bond for both services. | |
| 07/12/2019 | ELECTRIC - FINAL | Correction Required | 1-Install all devices with covers, or cover boxes. 2-Panel at service is not listed for wet location. 3-Need to install smoke detectors per Code. 4-Install grounding electrode conductor and connect it to ground rods per Code. |