Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2019 | PLUMBING - FINAL | Approved | complete previous correction of screws in b venting no tape please. | |
| 08/12/2019 | PLUMBING - FINAL | Not ready for Inspection | previous corrections not fixed correctly. Piping for T&P needs to be hard piped copper or galvanized 6 inches from finish floor. Flu venting not secured correctly. Missing shut off. 18 inches of copper piping required from shut off before changing to pex. | |
| 08/09/2019 | PLUMBING - FINAL | Correction Required | Complete termination for and P valve. Clearance SWG, OK to connect. |
|
| 08/08/2019 | PLUMBING - FINAL | Not ready for Inspection | Contractor cancelled, will reschedule for 9 August. |