Permit: T19CM04647

Parcel: 140241280


Addresses:

1219 E GINTER RD

Inspection Status: Passed

Inspection History: COT - RSBU - Excavation/Rebar/Zoning 

Date Description Inspector Results Comments
08/08/2019 COT - RSBU - Excavation/Rebar/Zoning  TVALENCIA Approved Entered by DMERANZ1 -
08/07/2019 COT - RSBU - Excavation/Rebar/Zoning  MHASSAN Not ready for Inspection Entered by DMERANZ1 - previous corrections still not fixed. Clearances need to be addressed, expansion joint still needs to be installed, rebar laps need to be 24 inches including on corners, plumbing needs to be backfilled and pipes need to be wrapped. I spoke with the homeowner on site and asked that if there are still issues with getting this fixed please have the guy doing the excavation and rebar work on site for next inspection.
08/05/2019 COT - RSBU - Excavation/Rebar/Zoning  AKLEINSORGE Partial Approval Entered by DMERANZ1 - Make sure 1/2" expansion joint material in installed where required and that 3" clearance is maintained in footing between rebar and soil. Do not pour until 3005 and 1015 inspections have been called in and approved