Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T19CM04263
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2020 | PLUMBING - FINAL | Approved | Ap | |
| 08/06/2019 | PLUMBING - FINAL | Denied | 1- Reference comments from previous inspection and make corrections as noted. | |
| 08/01/2019 | PLUMBING - FINAL | Denied | 1- Accessible water closet sidewall clearance is 16 to18 inches max from sidewall to center of water closet. 2- Shall provide a tank water closet flush handle to be located on the open side of room. 3- Grab bars shall be max 36 inches a.f.f. To the top of grab bar. 4- Toilet paper dispenser not located as per plan and ANSI standards check approved detail on plan. 5 I could not locate the tankless water heater or mixing valve at Lavatory. 6- provide Accessible signage on toilet room. |
|
| 07/30/2019 | PLUMBING - FINAL | Denied | 1- Doors were locked, please provide access to the inspection area at the time of inspection request. | |
| 06/17/2019 | PLUMBING - FINAL | Prior to Final Inspectn | WATER DISINFECTION REPORT REQUIRED |