Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - T19CM03880
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/07/2020 | COT - RSBU - Preslab | ESTEVENS | Approved | Entered by RSALDAT1 - RVI |
04/07/2020 | COT - RSBU - Preslab | ESTEVENS | Approved | Entered by RSALDAT1 - RVI |
03/09/2020 | COT - RSBU - Preslab | ESTEVENS | Not ready for Inspection | Entered by DMERANZ1 - not complete. |
03/03/2020 | COT - RSBU - Preslab | TVALENCIA | Denied | Entered by SFLORES2 - 1- Shall use the approved Solvent Cement for ABS material. 2- Shall provide a vent for the water closet or vent under the horizontal wet vent requirements. 3- Shall provide a water head test minimum of 5 feet above the highest fitting |
02/27/2020 | COT - RSBU - Preslab | ESTEVENS | Not ready for Inspection | Entered by SFLORES2 - not complete. |