Permit: T19CM03765

Parcel: 11942006L

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/05/2019 ELECTRIC - FINAL Approved
06/04/2019 ELECTRIC - FINAL Partial Approval Relocate smoke alarms in the bedrooms 6 to 12 inches below ceiling
Protect exposed wiring in storage room and hallway from physical damage
05/29/2019 ELECTRIC - FINAL Not ready for Inspection need smoke alarms in bedrooms 3 foot away from supply air, need smoke and carbon alarm outside of sleeping area. Need cover plates on receptacles and junction boxes with exposed wiring in hallway.