Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T19CM03765

Parcel: 11942006L

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
06/04/2019 ELECTRIC - RECONNECT Approved RECN
05/29/2019 ELECTRIC - RECONNECT Not ready for Inspection need smoke alarms in bedrooms 3 foot away from supply air, need smoke and carbon alarm outside of sleeping area. Need cover plates on receptacles and junction boxes with exposed wiring in hallway.