Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2019 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 07/23/2019 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | 1-Garage share wall edge nailing is too far apart. 2-Bedroom 2 shear wall has no nails in sill plate. 3-Install H2.5s on exterior studs top and bottom at 24" maximum spacing per IRC 802.11.1 as amended. |
|
| 07/18/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | No one on site, no inspections called in, no contact information, unable to determine which inspections are requested, provide contact information, or inspection codes. Provide address at jobsite as lot numbers do not show up on workforce. |