Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T19CM03560

Parcel: 112020170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/29/2019 EXT METAL CLIPS/EXT SHEATHING Approved
07/23/2019 EXT METAL CLIPS/EXT SHEATHING Correction Required 1-Garage share wall edge nailing is too far apart.
2-Bedroom 2 shear wall has no nails in sill plate.
3-Install H2.5s on exterior studs top and bottom at 24" maximum spacing per IRC 802.11.1 as amended.
07/18/2019 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection No one on site, no inspections called in, no contact information, unable to determine which inspections are requested, provide contact information, or inspection codes. Provide address at jobsite as lot numbers do not show up on workforce.