Permit: T19CM03448

Parcel: 130050820


Addresses:

1847 S OLSEN AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/20/2019 PLUMBING - FINAL Approved All corrections complete
05/16/2019 PLUMBING - FINAL Correction Required Secure all PEX where accessible at 32” OC per manuf using manufacturers listed pipe clamps.
Install 18” of copper at the water heater before attaching copper to flex at gas water heater. Manuf req to keep PEX from melting.