Permit: T19CM03062

Parcel: 103082600

Inspection Status: Passed

Inspection History: RSME - Mechanical Progress 

Date Description Inspector Results Comments
06/26/2019 RSME - Mechanical Progress  TVALENCIA Approved Entered by DMERANZ1 - 1- Shall provide a clean out at the base of the 2 inch waste stack. 2- ABS pipe is not approved material for blocking of horizontal piping. 3- Shall provide Shield plates at 3 inch soil stack. 4- Range electric conductor not secured and sheathing torn. 5- Shall secure the closet flange to floor. Inspection stop.