Inspection History Details
Inspection Status: Passed
Inspection History: COT - LCBU - Framing
Permit Number - T19CM03062
Inspection Description - COT - LCBU - Framing
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2019 | COT - LCBU - Framing | RCAMACHO | Approved | Entered by DMERANZ1 - |
07/05/2019 | COT - LCBU - Framing | TVALENCIA | Denied | Entered by VFLORES1 - |
07/01/2019 | COT - LCBU - Framing | DQUINN | Denied | Entered by DMERANZ1 - 1- ABS pipe is not approved material for blocking and support on horizontal waste and soil piping. 2- Shall secure and support horizontal water lines every 32 inches. 3- Shall support and block all horizontal waste and vent piping. |
06/28/2019 | COT - LCBU - Framing | RCAMACHO | Partial Approval | Entered by DMERANZ1 - 1/2” ab’s 64” oc all #2 shear walls Pending all trades |
06/26/2019 | COT - LCBU - Framing | TVALENCIA | Denied | Entered by DMERANZ1 - |