Permit: T19CM02996

Parcel: 130120880


Addresses:

3757 E ELLINGTON PL

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2019 ELECTRIC - INTERMEDIATE Approved
07/08/2019 ELECTRIC - INTERMEDIATE Not ready for Inspection Building locked up/no one on site at 12:10pm. No message left, recall and leave message with access instructions.
07/03/2019 ELECTRIC - INTERMEDIATE Correction Required NM/ Romex is not approved for under ground use. Use DB Cable at kitchen.
Install all missing J boxes.
New Service is required to have a gas pipe and metallic water pipe bond.
Receptacles required at the exterior-front and rear exit doors.
Staple/Strap all Romex in attic at 4’ 6" OC, minimum.