Permit: T19CM02996

Parcel: 130120880


Addresses:

3757 E ELLINGTON PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/18/2019 FRAMING Approved
07/12/2019 FRAMING Partial Approval follow details on page 4 on framing ceilings, each individual 2 x 4 is supported by a strut in the middle. Still need correct size T straps at patio per previous correction.
07/08/2019 FRAMING Not ready for Inspection Building locked up/no one on site at 12:10pm. No message left, recall and leave message with access instructions.
07/03/2019 FRAMING Correction Required Replace split roof rafter at interior wall of kitchen.
Plans do not reflect the ceiling framing done at the entry room at the front door
Patio post to beam require a T strap that connects the post to the beam as designed.
Anchor bolts required as discussed in the walk through.
Finish roof sheathing where old service panel still exists.
06/18/2019 FRAMING Not ready for Inspection Frame doesn’t get inspected until intermediates are complete.