Permit: T19CM02958

Parcel: 140420740

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/15/2019 PLUMBING - INTERMEDIATE Approved
10/11/2019 PLUMBING - INTERMEDIATE Denied 1- The 2 x 1 1/2 tap tee is approved in a vertical position only for the sink trap arm.
2- 2 inch C. O. Tee is approved in vertical position only.
3- The vent shall rise verticals from the trap arm.
4- Shall remove the test tee after water test approval by the p.o.c.
5- Shall conceal DWV system per note 41 or get exposed piping approval from the engineer.
6- Retest the system.