Inspection Status: Passed
Inspection History: COT - LCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 06/18/2019 |
COT - LCBU - Framing |
DMUNIZ |
Approved |
Entered by DMERANZ1 - |
| 06/17/2019 |
COT - LCBU - Framing |
AKLEINSORGE |
Partial Approval |
Entered by DMERANZ1 - 1. Missing H2.5 clips on trusses in master bedroom on interior load bearing wall
2. Missing stud at master bedroom entry on exterior wall |