Permit: T19CM02762

Parcel: 140326180


Addresses:

5980 S TAPPEN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T19CM02762

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/10/2019 EXT METAL CLIPS/EXT SHEATHING Approved All corrections complete, except as follows: floor trusses not sitting flat on bearing wall top plates need shims and truss over stairs is not to code, contractor is going to move stairs back to allow for proper height clearance, both theses items can be inspected at framing inspection
06/06/2019 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection if floor trusses are not sitting flat on bearing wall top plates make sure to shim them. Truss over stairs is not to code, 7 foot clearance required above step, currently it is at 6’ 2". This may need engineering. Studs that have mold on them need to be treated. Missing nails in floor sheathing at north east bedroom upstairs floor is squeaking. Missing two sheer walls second-floor.