Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T19CM02744
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2019 | MECHANICAL - INTERMEDIATE | Approved | (rvi) | |
09/13/2019 | MECHANICAL - INTERMEDIATE | Partial Approval | Provide support at gas piping, provide swing joint at condensate to remove stress on fittings, Horizontal support of PVC not to exceed 48 inches, provide minimum clearance to combustible’s at upstairs venting of water heater. |