Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2019 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 12/04/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | Cancel by contractor | |
| 11/27/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | No approved truss drawing. Missing H2.5 clips. Missing nails on north east side in sheathing. STOPPED INSPECTION | |
| 11/13/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Inspection was to inspect new j bolts on top of existing block walls. Need 2 j bolts per plate section on east and west walls, other than being 32" oc. After plates are installed, 4’ of coil strap must be installed on each corner’s plates. |