Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19CM02404

Parcel: 141361490

Inspection Status: Passed

Inspection History: COT - LCBU - Framing

Permit Number - T19CM02404

Inspection Description - COT - LCBU - Framing

Inspection Status - Passed

Date Description Inspector Results Comments
06/20/2019 COT - LCBU - Framing MHASSAN Approved Entered by DMERANZ1 -
06/19/2019 COT - LCBU - Framing AKLEINSORGE Partial Approval Entered by DMERANZ1 - 1. Shim floor trusses along front entry wall 2. Need FHA strap at 3 top plate over bore locations on 1st level 3. Nail protection plate on dwv line at 2nd level near stairs 4. Fire foam penetration in master bedroom closet and around waste line in guest bathroom 5. Floor truss in garage needs hanger installed at Glue lam or be stitched to other floor truss completely