Permit: T19CM02346

Parcel: 130083760


Addresses:

3656 E SYLVANE ST

Inspection Status: Not Applicable

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
06/10/2019 ELECTRIC - RECONNECT Not Applicable
05/09/2019 ELECTRIC - RECONNECT Correction Required 2 ground rods, water bond and gas bond required. Label all breaker functions.
Re-thread service mast as present is cross threaded ; this may require a power cut. Level up panel and install all weather tight Ferrell’s on emt branch lines leaving the panel. If power cut then service entrance cables should be updated to 2/0 copper or 4/0 aluminum as required for a 200 amp Panel.