Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/31/2019 |
BUILDING - FINAL |
|
Approved |
according to drawings "existing ADA restroom". This ADA restroom has a few violations please fix these. Door handle needs to be a lever not a knob. Reflective surface on mirror cannot be more than 40 inches high. Sink needs scald guards. ADA signage needs to be visible and within reach. |
| 05/08/2019 |
BUILDING - FINAL |
|
Not ready for Inspection |
back door either needs a panic bar or signage saying door to remain unlocked during business hours. Drawings are calling for ADA restroom, several ADA items incorrect, please follow detailed drawing on page 3 on the ADA restroom requirements. Make sure path of egress is clear. Receptacles need cover plates. Also pending fire and engineering’s approval. |
| 05/07/2019 |
BUILDING - FINAL |
|
Partial Approval |
Pending engineering and fire finals |
| 05/06/2019 |
BUILDING - FINAL |
|
Partial Approval |
pending fire and engineering finals |