Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T19CM02320
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/31/2019 | BUILDING - FINAL | Approved | according to drawings "existing ADA restroom". This ADA restroom has a few violations please fix these. Door handle needs to be a lever not a knob. Reflective surface on mirror cannot be more than 40 inches high. Sink needs scald guards. ADA signage needs to be visible and within reach. | |
| 05/08/2019 | BUILDING - FINAL | Not ready for Inspection | back door either needs a panic bar or signage saying door to remain unlocked during business hours. Drawings are calling for ADA restroom, several ADA items incorrect, please follow detailed drawing on page 3 on the ADA restroom requirements. Make sure path of egress is clear. Receptacles need cover plates. Also pending fire and engineering’s approval. | |
| 05/07/2019 | BUILDING - FINAL | Partial Approval | Pending engineering and fire finals | |
| 05/06/2019 | BUILDING - FINAL | Partial Approval | pending fire and engineering finals |