Inspection History: FRAMING

Date Description Inspector Results Comments
06/13/2019 FRAMING Approved
06/12/2019 FRAMING Denied 1. Need blocking between combustion and fresh air vents in garage.
2. Need to completely nail FHA plate over line set on both levels (8 nails per side)
3. Fire foam top plate penetrations on both levels
4. Shim 2 floor trusses in front hallway at garage wall top plate