Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2019 |
ELECTRIC - RECONNECT |
|
Approved |
OK to clear electric RECN |
| 03/25/2019 |
ELECTRIC - RECONNECT |
|
Not ready for Inspection |
smoke alarms needed in each sleeping area 3 feet away from supply air. Carbon monoxide alarm needed outside of sleeping area. Cover plates needed at exposed receptacles and switches. Kitchen and bathroom circuits and their receptacles are on a three prong system and need to be GFCI protected. 30 amp receptacle in garage is run off an extension cord. Junction box in garage ceiling needs cover plate. Exposed wiring and incorrect wiring done at water heater and back patio. Recommend getting a licensed electrician to make these repairs. |