Permit: T19CM02056

Parcel: 132131010


Addresses:

2985 S KINO PW

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/05/2020 BUILDING - FINAL Approved Approved
11/02/2020 BUILDING - FINAL Not ready for Inspection Not Ready, recall inspection and leave contact information
10/20/2020 BUILDING - FINAL Partial Approval INSPECTOR APPROVED BUILDING FINAL. PENDING SPECIAL INSPECTIONS.
08/13/2020 BUILDING - FINAL Cancelled CA
1- Contractor cancelled the inspection request.
08/12/2020 BUILDING - FINAL Partial Approval partial
1- Shall provide Trap Guards on the restroom floor drains.
2- Service Counter maximum height above finish floor shall be 34 inches.
3- Shall label the Electric Service Panels.
4- Shall provide the missing emergency light.
08/10/2020 BUILDING - FINAL Denied denied
1- There was no contact number or message given on the inspection request.