Permit: T19CM01848

Parcel: 107132720


Addresses:

526 E KELSO ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS RECONNECT

Date Description Inspector Results Comments
04/23/2019 PLUMBING - GAS RECONNECT Approved
04/19/2019 PLUMBING - GAS RECONNECT Not ready for Inspection Work is incomplete
04/17/2019 PLUMBING - GAS RECONNECT Denied 1- Shall install the water heater at time of final inspection.
2- Shall provide a gas bond on system
3- Shall hard pipe thru the furnace housing the locate the flex connector and gas shut off valve.
4- Shall secure and strap down gas piping.
5- Shall provide a carbon monoxide detector located in hallway.
6- re test the system.
03/19/2019 PLUMBING - GAS RECONNECT Denied 1- The gas pressure test was below the required pressure of 3 psi, check system for leaks.
2- Shall connect all gas appliances.
3- Shall obtain a water heater permit.
4- Shall hard pipe thru the furnace housing then connect he gas shut off valve, sediment trap and flex connector.
5- Shall provide a carbon monoxide detector for both hallways that lead to the bedrooms.
6- A gas Water Heater Shall not be located in the bedroom closet and requires combustion air vents that do not communicate to the bedroom.
03/15/2019 PLUMBING - GAS RECONNECT Not ready for Inspection System not under test