Permit: T19CM01848

Parcel: 107132720


Addresses:

526 E KELSO ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/23/2019 PLUMBING - GAS PRESSURE TEST Approved
04/19/2019 PLUMBING - GAS PRESSURE TEST Not ready for Inspection Work is incomplete
04/17/2019 PLUMBING - GAS PRESSURE TEST Denied 1- Shall install the water heater at time of final inspection.
2- Shall provide a gas bond on system
3- Shall hard pipe thru the furnace housing the locate the flex connector and gas shut off valve.
4- Shall secure and strap down gas piping.
5- Shall provide a carbon monoxide detector located in hallway.
6- re test the system.
04/16/2019 PLUMBING - GAS PRESSURE TEST Denied 1- Gate was locked, no access at the time of inspection request.