Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2019 | RESIDENTIAL INTERMEDIATE | Approved | ||
| 09/18/2019 | RESIDENTIAL INTERMEDIATE | Denied | No access, no contact information. | |
| 09/17/2019 | RESIDENTIAL INTERMEDIATE | Denied | 1- Shall seal all top plate penetrations with fire rated foam or caulk as requested. 2- Shall provide (3) sided blocking on forced air vents as requested. 3- Shall provide protection for the exposed Sanitary waste and vent for he laundry. |
|
| 09/05/2019 | RESIDENTIAL INTERMEDIATE | Denied | 1- Shall provide an approved two hole strap on the line set for AC. P- tape is not approved material. 2- Shall seal all top plate penetrations with fire rated foam or caulk. 3- There are numerous H 2.5 clips that are missing nails. 4- There are some electric conductors that are not secured at box. 5- The Stove exhaust is incomplete 6- Supply duct requires (3) sided blocking at Bonus room. 7- Range electric box not installed 8- Note: The existing Bonus/Storage/Laundry Room does not meet the minimum ceiling height of 7 feet AFF for habitable space. |
|
| 06/25/2019 | RESIDENTIAL INTERMEDIATE | Denied | All new work done must be on approved plans. Approved plans to show new framing, electrical, plumbing and mechanical. Provide stamped approved COT truss calls prior to framing inspection. No inspection done at this time |