Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19CM01395

Parcel: Unknown

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - T19CM01395

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Passed

Date Description Inspector Results Comments
05/07/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing DQUINN Approved Entered by CBELL1 -
05/03/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing DQUINN Denied Entered by CBELL1 - 1. Strap patio door gluelam to intersecting top plates on both ends. Same on exterior southwest gluelam. 2. Nail osb to both st hold down studs to top plate. 3. Entry trusses need h2.5 clips at south end.