Inspection History Details
Inspection Status: Not Applicable
Inspection History: FIREWALL/FIREBARRIER/FIRESTOP
Permit Number - T19CM01385
Inspection Description - FIREWALL/FIREBARRIER/FIRESTOP
Inspection Status - Not Applicable
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2019 | FIREWALL/FIREBARRIER/FIRESTOP | Not Applicable | See letterhead from architect of record Thomas Sayler Brown per details two and three on sheet aA1.0 calls for fire caulk. It is acceptable to use acoustical sealant instead , since the demising wall is not required to be fire rated for M occupancy. No separation is required. Contractor made hole in Sheetrock to verify 2 layers of 5/8” Sheetrock each side |