Permit: T19CM01191

Parcel: 10510010D

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/19/2019 PLUMBING - INTERMEDIATE Approved
03/18/2019 PLUMBING - INTERMEDIATE Denied 1- Shall provide isolators on all metal studs that have water lines passing thru.
2- Shall provide a hanger on horizontal vent.
3- Shall secure the water line drops.
4- Shall remove the threaded test tee in wall and provide a pup splice. No threaded fittings allowed in a concealed location.
5- DWV water test provided.